ZD500R: Calibrate from Printer's Interface

Step 1: Media Calibration

Hold the PAUSE + CANCEL buttons for 2 seconds to start the media calibration.

Step 2: RFID Calibration

Press the menus ‘Home’ (zd500r home.png) button. Navigate to the ‘RFID’ (zd500r rfid.png) menu button and press the ‘Select’ ( ) button.

Use the Left and Right navigation arrows to browse to the RFID CALIBRATE procedure. Press the select button ( ) below the START on the lower right hand of the display.

The printer will slowly feed a label while adjusting the location and RFID read/write communication settings for your chosen RFID tag/label.

The printer will feed an additional label in some cases when calibration has completed successfully with the display message reading: READY

At this point, you can open the printer and roll the excess labels back inside. Then, close the printer, unpause it, and you will be ready to print.