ZD500R: Calibrate from Printer's Interface

Step 1: Media Calibration

Hold the PAUSE + CANCEL buttons for 2 seconds to start the media calibration.

Step 2: RFID Calibration

2. Press the menus ‘Home’ ( ) button. Navigate to the ‘RFID’ ( ) menu button and press

the ‘Select’ (4) button.

3. Use the ‘Left’ () and ‘Right’ () navigation arrows to browse to the ‘RFID

CALIBRATE’ procedure. Press the select button (—) below the START on the lower

right hand of the display.

4. The printer will slowly feed a label while adjusting the location and RFID read/write

communication settings for your chosen RFID tag/label.

The printer will feed an additional label in some cases when calibration has completed

successfully with the display message reading: READY

5. Remove excess media. Media calibration has finished and you are ready to print.